Engineering Note: All properties per IS 808:2021. Fy and Fu are nominal values per IS 2062:2011 — use actual mill certificate values for design. Plastic modulus Sxx used for plastic design per IS 800:2007 Clause 8.2.2. Radius of gyration ryy governs lateral-torsional buckling (Cl. 8.3). Always verify dimensions against current edition of IS 808 before use in fabrication drawings.

Section ↕ h mm b mm tw mm tf mm A cm² G kg/m Ixx cm⁴ Wxx cm³ Sxx cm³ rxx cm Iyy cm⁴ Wyy cm³ ryy cm Producers